Features and Specifications

iVAC Pro Tool: T11515NA, T11520NA, T24020NA, to be replaced by iVAC Pro Tool Plus.

Features

  • Three Modes of operation. Auto – Off – On
  • Four System addresses. Programmable
  • One of eight Tool Addresses. Programmable

Specifications

  • Voltage is either 115Vac or 240Vac dependant on model
  • Current capacity is either 15Amps or 20Amps, dependant on model
  • Circuit breakers are rated at 15Amps or 20Amps, dependant on model
  • Input power cord is 30” with the respective NEMA straight blade plug
  • Output power receptacle is the respective NEMA straight blade receptacle
  • Active sense current, 0.3Amps for T115xxNA units and 0.5Amps for T24020NA.
  • Range, 40’ line of sight
  • Maximum ambient operating temperature, 30C
  • Regulatory approval
    TUV certification to UL60950-1 and CSA 60950-1
    FCCID : YCH-IVACRFM
    IC  8940A-IVACRFM

iVAC Pro Switch: S11515NA, S11520NA, S24020NA.

Features

  • Three Modes of operation. Auto – Off – On
  • Four System addresses. Programmable
  • Turn On Delay
  • Turn Off Time – Programmable
  • Master Reset

Specifications

  • Voltage is either 115Vac or 240Vac dependant on model
  • Current capacity is either 15Amps or 20Amps, dependant on model
  • Circuit breakers are rated at 15Amps or 20Amps, dependant on model
  • Typical Motor drive capability
    1HP at 115vac
    2.0HP at 240Vac
  • Input power cord is 30” with the respective NEMA straight blade plug
  • Output power receptacle is the respective NEMA straight blade receptacle
  • Turn ON Delay 0 or 1.5 seconds
  • Turn Off Time 0, 5, 15 or 45seconds
  • Range, 40’ line of sight
  • Maximum ambient operating temperature, 30C
  • Regulatory approval
    TUV certification to UL60950-1 and CSA 60950-1

BCT iVAC advises that the iVAC Contactor must be used for 1.5HP dust collectors operating on 115Vac and for any dust collector over 2.0HP operating on 230Vac.